Avionics Solutions
 
Dynon

HOME

 

JPI EDM 930

 

 

Think of your EDM-930 as your personal flight engineer. Always there, working in the background, constantly watching over your engine while you concentrate on flying the aircraft. Your EDM-930 will be monitoring your engine conditions four times per second and will warn you instantly if any measurement exceeds the programmed limit.
 
Leaning is accomplished quickly and automatically using the LeanFind™ procedure. With the EDM it is now possible to have substantially more diagnostic information available to you in a timely and usable manner.
 
The EDM 930 collects data and displays it for you in a useful way. You can use the EDM 930 to monitor engine temperatures and voltages, adjust the fuel/air mixture, and diagnose engine malfunctions.

  Standard feature EDM 930        
 
  • Hands-free, automatic scanning
  • All programming done from the Front Panel
  • LeanFind™ finds the first and last cylinder to peak with true
  • peak detect eliminates false peaks
  • Displays both leaned temperature below peak and peak
  • Battery voltage with alarm
  • Amperes (load or charge/discharge meter)
  • Programmable alarm limits
  • Normalize view
  • Exhaust Gas Temperatures (EGTs) to stable 1°F resolution
  • DIF low to high EGT with alarm
  • EGTs to stable 1°F resolution
  • Shock cooling monitored on every cylinder
  • Shock cooling monitored on every cylinder
  • User selectable index rate
  • Fast response probes
  • Non-volatile long term memory
  • Records and stores data up to 30 hours
  • Post-flight data retrieval
  • Download to Palm™ Computer
  • Data retrieval software
  • Oil pressure
  • Oil temperature
  • Outside air temperature
  • Fuel level
  • Fuel Flow
  • Solid-state rotor fuel flow transducer
  • Fuel quantity in gallons, kilograms, liters, or pounds
  • Low fuel quantity alarm
  • Low fuel time alarm
  • GPS interface
  • Instantaneous fuel flow rate
  • Total amount of fuel consumed
  • Total fuel remaining
  • Time to empty at the curent fuel flow rate
  • RPM and manifold pressure
  • Automatically calculates percent horsepower
  • History of extreme values during previous flight
  • Hobbs® timer

 

JPI EDM 930

 

RPM and MAP Section Display

The upper semicircular bar graph shows the RPM (Revolutions per Minute) and the lower semicircular bar graph shows the MAP (Manifold Pressure). These are shown both graphically and digitally. Power settings entering red line are displayed by flashing the ALERT icon and flashing message on the bottom left scanner section of the screen. Percent horsepower is displayed digitally underneath the MAP arc.

Bar Graph Section Display

The Bar Graphs section contains nine dedicated 12 segment bar graphs with digital display. The default displays are (left to right, top to bottom):  

- Oil temperature
- Oil pressure
- Fuel pressure
- Bus voltage
- Amps load or charge/discharge
- Outside air temperature (or owner selectable )
- Fuel flow, units per hour
- Left fuel quantity (or owner selectable)
- Right fuel quantity (or owner selectable)
 
 
The top of the bar is redline and the bottom of the bar is zero for O-T, OP, F-P, amps load. For amps charge/discharge the center of the bar is zero and the top and bottom is redline charge and discharge, respectively. For volts the top of the bar is high redline and the bottom of the bar is low redline.
The top of the bar for Fuel Flow is set by the MAX FF parameter. The white horizontal line indicates  freezing for OAT.

Basic Scanner Operations

Let’s examine the scanner section analog display. Central to the display is the exhaust gas temperature— or EGT— bar graph presentation. The height of each column represents the EGT. The last column shows turbine inlet temperature. The range of the EGT columns is red line at the top down to one half of red line at the bottom. This is called the percentage view because you are looking at a percentage of red line. The Normalize view allows you to see small, subtle changes in temperature. When you change to the Normalize view—hold the Lean Find button for three seconds all column heights are set to the identical half-height. Any changes are shown as an increase or decrease in column height. A one-bar change in column height represents a 10 degrees change.  

The Normalize view permits rapid visualization of EGT trends, rather than a percentage of red line. The missing segment in the column represents the cylinder head temperature. Above each column is a number corresponding to the engine cylinder number. The rightmost column displays turbine inlet temperature. Beneath the bar graph is the alphanumeric display. A single index dot above one column indicates which cylinder is being displayed on this numerical display. When the index dot is beneath a cylinder number, 1 through 6, the digital display shows the EGT on the left four digits and the CHT on the right three digits. Two other derived measurements are shown in this display:
 
·        The rate of shock cooling of the most rapidly cooling cylinder, in degrees per minute. Lycoming recommends that you keep this value below 50 degrees per minute.

·        The difference between the hottest and coolest exhaust gas temperatures.

JPI EDM 930

EGT

EGT is shown on the first four or six Scanner bar graph columns. These are labeled 1 through 4 or 1 through 6 above the columns. The lower limit of the graph range represents half of the TIT alarm red line (default is 825°F) and the top of the range represents alarm red line (default 1650°F). The numerical value of the EGT is shown on the left side of the digital display for each cylinder when there is a dot under one of the cylinder numbers above the column—cylinder 2 in this example. There are two views: Normalize view levels the EGT columns and increases the sensitivity of the Scanner bar graph columns to 10° per segment. To enter the Normalize view, hold the LeanFind button for three seconds. The NRM icon will be displayed above the Scanner section. Hold the LeanFind button for three seconds to return to the Percentage view.

CHT

The Cylinder Head Temperature—CHT—is represented by a missing segment in the Scanner bar graph column. If the EGT is too low for there to be a missing segment, the CHT is represented by a lone segment in that column. The scale is shown to the left side of the columns. The numerical value of the CHT is shown on the right side of the digital display for each cylinder when there is a dot under one of the cylinder numbers above the column.



 

 

HOME

Avionics Solutions

asllc@myavionicsteam.com